relacs

Relaxed Electrophysiological Data Acquisition,
Control, and Stimulation

... enjoy your recordings

ThresholdLatencies  [RePro]  [Patch-Clamp-Projects Plugins]

Measures spike latencies in response to pulses close to the firing threshold.

Author
Jan Benda
Version
1.2 (Nov 03, 2010)
Options
  • Test-Pulse
  • durationsel=in milliseconds: Set duration of stimulus (string)
  • duration=100ms: Duration of stimulus (number)
  • durationfac=1tau_m: Duration of stimulus (number)
  • startamplitudesrc=custom: Set initial amplitude to (string)
  • startamplitude=0.1nA: Initial amplitude of current stimulus (number)
  • startamplitudestep=0.1nA: Initial size of amplitude steps used for searching threshold (number)
  • amplitudestep=0.01nA: Final size of amplitude steps used for oscillating around threshold (number)
  • adjust=DC: Adjust (string)
  • First Pre-Pulse
  • preduration=0ms: Duration of first pre-pulse stimulus (number)
  • preamplitudesrc=custom: Set amplitude of first pre-pulse to (string)
  • preamplitude=0.1nA: Amplitude of first pre-pulse stimulus (number)
  • prevcamplitude=0mV: Voltage clamp value of first pre-pulse (number)
  • prevcgain=0mS: Gain for voltage clamp of first pre-pulse (number)
  • prepulseramp=none: Start first pre-pulse with a ramp (string)
  • prepulserampwidth=0ms: Width of the ramp (number)
  • Second Pre-Pulse
  • pre2duration=0ms: Duration of second pre-pulse stimulus (number)
  • pre2amplitudesrc=custom: Set amplitude of second pre-pulse to (string)
  • pre2amplitude=0.1nA: Amplitude of second pre-pulse stimulus (number)
  • Post-Pulse
  • postduration=0ms: Duration of post-pulse stimulus (number)
  • postamplitudesrc=custom: Set post-pulse amplitude to (string)
  • postamplitude=0.1nA: Amplitude of post-pulse stimulus (number)
  • Timing
  • searchpause=500ms: Duration of pause between outputs during search (number)
  • pause=1000ms: Duration of pause between outputs (number)
  • delay=50ms: Time before stimullus onset (number)
  • savetracetime=500ms: Length of trace to be saved and analyzed (from test-pulse on) (number)
  • repeats=10: Repetitions of stimulus (integer)
Key shortcuts
  • M: Start measuring now.

Possible stimulus configurations are shown in the figure:

thresholdlatenciesstimuli.png

The left column shows the stimuli without a DC input whereas in the right column stimuli starting out from a preset DC input (for example by the RePro SetDC) are shown. Stimuli A and B are the standard test protocol, whereas for testing out the dynamics stimuli F and G might be most usefull.

Last modified: Wed Jun 13 16:31:30 CEST 2018 Valid HTML 4.01 Transitional