Measures spike latencies in response to pulses close to the firing threshold.
- Author
- Jan Benda
- Version
- 1.2 (Nov 03, 2010)
- Options
- Test-Pulse
durationsel=in
milliseconds: Set duration of stimulus (string
)
duration=100ms
: Duration of stimulus (number
)
durationfac=1tau_m
: Duration of stimulus (number
)
startamplitudesrc=custom:
Set initial amplitude to (string
)
startamplitude=0.1nA
: Initial amplitude of current stimulus (number
)
startamplitudestep=0.1nA
: Initial size of amplitude steps used for searching threshold (number
)
amplitudestep=0.01nA
: Final size of amplitude steps used for oscillating around threshold (number
)
adjust=DC:
Adjust (string
)
- First Pre-Pulse
preduration=0ms
: Duration of first pre-pulse stimulus (number
)
preamplitudesrc=custom:
Set amplitude of first pre-pulse to (string
)
preamplitude=0.1nA
: Amplitude of first pre-pulse stimulus (number
)
prevcamplitude=0mV
: Voltage clamp value of first pre-pulse (number
)
prevcgain=0mS
: Gain for voltage clamp of first pre-pulse (number
)
prepulseramp=none:
Start first pre-pulse with a ramp (string
)
prepulserampwidth=0ms
: Width of the ramp (number
)
- Second Pre-Pulse
pre2duration=0ms
: Duration of second pre-pulse stimulus (number
)
pre2amplitudesrc=custom:
Set amplitude of second pre-pulse to (string
)
pre2amplitude=0.1nA
: Amplitude of second pre-pulse stimulus (number
)
- Post-Pulse
postduration=0ms
: Duration of post-pulse stimulus (number
)
postamplitudesrc=custom:
Set post-pulse amplitude to (string
)
postamplitude=0.1nA
: Amplitude of post-pulse stimulus (number
)
- Timing
searchpause=500ms
: Duration of pause between outputs during search (number
)
pause=1000ms
: Duration of pause between outputs (number
)
delay=50ms
: Time before stimullus onset (number
)
savetracetime=500ms
: Length of trace to be saved and analyzed (from test-pulse on) (number
)
repeats=10
: Repetitions of stimulus (integer
)
- Key shortcuts
-
Possible stimulus configurations are shown in the figure:
The left column shows the stimuli without a DC input whereas in the right column stimuli starting out from a preset DC input (for example by the RePro SetDC) are shown. Stimuli A and B are the standard test protocol, whereas for testing out the dynamics stimuli F and G might be most usefull.