Measures spike latencies in response to pulses close to the firing threshold.
- Author
- Jan Benda
- Version
- 1.2 (Nov 03, 2010)
- Options
- Test-Pulse
durationsel=in milliseconds: Set duration of stimulus (string)
duration=100ms: Duration of stimulus (number)
durationfac=1tau_m: Duration of stimulus (number)
startamplitudesrc=custom: Set initial amplitude to (string)
startamplitude=0.1nA: Initial amplitude of current stimulus (number)
startamplitudestep=0.1nA: Initial size of amplitude steps used for searching threshold (number)
amplitudestep=0.01nA: Final size of amplitude steps used for oscillating around threshold (number)
adjust=DC: Adjust (string)
- First Pre-Pulse
preduration=0ms: Duration of first pre-pulse stimulus (number)
preamplitudesrc=custom: Set amplitude of first pre-pulse to (string)
preamplitude=0.1nA: Amplitude of first pre-pulse stimulus (number)
prevcamplitude=0mV: Voltage clamp value of first pre-pulse (number)
prevcgain=0mS: Gain for voltage clamp of first pre-pulse (number)
prepulseramp=none: Start first pre-pulse with a ramp (string)
prepulserampwidth=0ms: Width of the ramp (number)
- Second Pre-Pulse
pre2duration=0ms: Duration of second pre-pulse stimulus (number)
pre2amplitudesrc=custom: Set amplitude of second pre-pulse to (string)
pre2amplitude=0.1nA: Amplitude of second pre-pulse stimulus (number)
- Post-Pulse
postduration=0ms: Duration of post-pulse stimulus (number)
postamplitudesrc=custom: Set post-pulse amplitude to (string)
postamplitude=0.1nA: Amplitude of post-pulse stimulus (number)
- Timing
searchpause=500ms: Duration of pause between outputs during search (number)
pause=1000ms: Duration of pause between outputs (number)
delay=50ms: Time before stimullus onset (number)
savetracetime=500ms: Length of trace to be saved and analyzed (from test-pulse on) (number)
repeats=10: Repetitions of stimulus (integer)
- Key shortcuts
-
Possible stimulus configurations are shown in the figure:
The left column shows the stimuli without a DC input whereas in the right column stimuli starting out from a preset DC input (for example by the RePro SetDC) are shown. Stimuli A and B are the standard test protocol, whereas for testing out the dynamics stimuli F and G might be most usefull.