VICurve  [RePro]  [Patch-Clamp Plugins]

V-I curve measured in current-clamp

Author
Jan Benda
Version
1.2 (Sep 11, 2014)
Screenshot
vicurve.png
Options
  • Stimuli
  • ibase=zero: Currents are relative to (string)
  • imin=-2nA: Minimum injected current (number)
  • imax=1.5nA: Maximum injected current (number)
  • istep=0.1nA: Minimum step-size of current (number)
  • userm=true: Use membrane resistance for estimating istep from vstep (boolean)
  • vstep=2mV: Minimum step-size of voltage (number)
  • Timing
  • duration=500ms: Duration of current output (number)
  • delay=100ms: Delay before current pulses (number)
  • pause=1000ms: Duration of pause between current pulses (number)
  • ishuffle=AlternateOutUp: Initial sequence of currents for first repetition (string)
  • shuffle=Random: Sequence of currents (string)
  • iincrement=-3: Initial increment for currents (integer)
  • singlerepeat=1: Number of immediate repetitions of a single stimulus (integer)
  • blockrepeat=5: Number of repetitions of a fixed intensity increment (integer)
  • repeat=100: Number of repetitions of the whole V-I curve measurement (integer)
  • Analysis
  • vmin=-120mV: Minimum value for membrane voltage (number)
  • sswidth=100ms: Window length for steady-state analysis (number)
  • ton=20ms: Timepoint of onset-voltage measurement (number)
  • plotstdev=true: Plot standard deviation of membrane potential (boolean)