Assess spike precision in locust auditory receptors
- Author
- Samuel Glauser
-
Jan Benda
- Options
- Stimulus
freqrange=: Frequency range (string)
amplitude=4dB: Amplitude of envelope (number)
intensity=80dB SPL: Stimulus intensity (number)
intensitybase=SPL: Stimulus intensity relative to (string)
repeats=10times: Number of stimulus presentations (number)
duration=500ms: Duration of stimulus (number)
pause=1000ms: Duration of pause between stimuli (number)
carrierfreq=5kHz: Carrier frequency (number)
usebestfreq=true: Use the cell's best frequency (boolean)
side=left: Speaker (string)
- Waveform
waveform=sine: Type of amplitude modulation (string)
dutycycle=50%: Duty-cycle of rectangular waveform (number)
stimfile=: Stimulus file (string)
stimampl=0: Amplitude factor (standard deviation) of stimulus file (number)
relfreqgap=20%: Relative width of frequency gap (number)
absfreqgap=10Hz: Absolute width of frequency gap (number)
rescale=true: Rescale filtered noise-gap stimuli (boolean)
ramp2=0ms: Ramp for rectangles and saw tooths (number)
ramp=2ms: Ramp at beginning and end of stimulus (number)
- Intensity - search
userate=true: Search intensity for target firing rate (boolean)
rate=100Hz: Target firing rate (number)
ratetol=5Hz: Tolerance for target firing rate (number)
intensitystep=8dB: Initial intensity step (number)
searchrepeats=2times: Number of search stimulus presentations (number)
- Analysis
skipwin=200ms: Initial portion of stimulus not used for analysis (number)
sigma1=1ms: Standard deviation of rate smoothing kernel 1 (number)
sigma2=20ms: Standard deviation of rate smoothing kernel 2 (number)
- Save stimuli
storemode=session: Save stimuli in (string)
storepath=: Save stimuli in custom directory (string)
- Version
- 1.5 (Jan 10, 2008)